Preface
With this Installation, Operation and Maintenance Manual, BATUSAN is committed to your personal safety and to the long service life of Underground Ball Valves. This manual provides the safety guidelines for the valves, including information on handling, storage, installation into the pipeline, burial, operation and maintenance. Please read it carefully before installing, operating or maintaining the valve.
BATUSAN provides general guidelines in this manual. The end user must therefore take responsibility for the correct valve selection, sizing, installation, operation and maintenance of Batusan valve products. The end user must read this document in conjunction with the drawings, test certificates and instructions supplied with the product (for example the gearbox or actuator manual).
Purpose
The UNDERGROUND BALL VALVE is a fully welded, trunnion-mounted ball valve designed to be buried directly in the soil together with the pipeline. It directs, transmits or stops the flow by the movement of the ball inside its body, and it is operated from the ground surface by means of a stem extension. The purpose of this manual is to ensure that the valve is installed, buried and operated in accordance with the valve conditions, so that it can fulfil its working principles throughout its service life.
Because a buried valve cannot be reached for routine maintenance once it is covered, the correct execution of the installation and burial steps in this manual is decisive for its service life.
The user is responsible for the problems and consequences arising from behaviour contrary to the specified issues.
General information and technical data
Thanks to their low weight, high endurance and space-saving features, Batu fully welded ball valves are used in transmission and distribution pipelines. Depending on the intended purpose, they are used in underground and aboveground applications. In the underground version, the stem is extended to the ground surface inside a protective extension housing, and the vent, drain and sealant injection lines are brought up to the top of the extension.
Features
- Trunnion-mounted ball; ball and stem independent of each other
- Fully welded body: no body bolts, no body joint leak path to the soil
- Anti-static design
- Fire-safe design
- Anti-blowout stem: the stem cannot be ejected from the valve by internal pressure
- Soft seat and metal seat options
- Butt-weld ends with pipe pups, or flanged ends
| Technical data | Value |
|---|---|
| Sizes | 2" – 24" (DN 50 – DN 600) |
| End connections | BW (butt weld), RF, RTJ, SW |
| Pressure class | Class 150 / 300 / 600 (PN 20 / 50 / 100) |
| Working temperature | −29 °C … +180 °C (catalogue range; the actual limits depend on the seat and seal materials and are given on the valve label) |
| Operation | T-key, gearbox with handwheel, pneumatic / hydraulic / electric actuator |
| Stem extension height H | Made to the burial depth specified in the order (catalogue range 800 – 1200 mm) |
| Pipe pup length | Per order (catalogue range 300 – 500 mm) |
| Valve design | API 6D / ISO 14313 / ISO 17292 / ASME B16.34 |
| Face-to-face | ASME B16.10 |
| End connections | ASME B16.25 / ASME B16.5 / EN 1092-1 |
| Testing | API 6D / API 598 / ISO 14313 |
| Fire safe | API 6FA / API 607 / ISO 10497 |
| Isolation type | DBB / DIB-1 / DIB-2 |
Technical data of Batu underground (fully welded) ball valves / Batu yeraltı (tam kaynaklı) küresel vanalarının teknik özellikleri
Seat types and the body cavity
- Single piston effect (SPE): standard seat type. If the pressure in the body cavity rises above the line pressure while the valve is closed, the seat is pushed back and the cavity pressure is released to the low-pressure side of the line (self-relieving).
- Double piston effect (DPE): optional seat type. The seats are pushed towards the ball whether the pressure comes from the line or from the body cavity, so the body cavity is not relieved automatically; the use of a drain (blow-down) valve is recommended.
- SPE-DPE: self-relieving seat on one side, double barrier on the other. The cavity pressure is relieved through the SPE seat side; the preferred installation direction indicated on the valve must be observed.
The seat type of your valve is given in the order documents and on the valve label.
Parts list
| No | Part |
|---|---|
| 1 | Body |
| 2 | Cover (end piece) |
| 3 | Ball |
| 4 | Stem (action spindle) |
| 5 | Seat ring |
| 6 | Ball sealing element (seat insert) |
| 7 | Body O-ring |
| 8 | Cover O-ring |
| 9 | Seat ring O-ring |
| 10 | Spring |
| 11 | Neck |
| 12 | Neck sealing element |
| 13 | Neck O-ring |
| 14 | Neck bolt |
| 15 | Neck sealing element |
| 16 | Graphite packing ring |
| 17 | Stem O-ring |
| 18 | Pressure ring |
| 19 | Disc spring (bowl washer) |
| 20 | Counter nut |
| 21 | Stud |
| 22 | Nut |
| 23 | Blow-down valve |
| 24 | Blow-down pipe |
| 25 | Vent / drain / injection line valves |
| 26 | Top plate (pipe support sheet) |
| 27 | Vent / drain / sealant lines |
| 28 | Sealant (grease) injection fitting |
| 29 | Ball support (trunnion block) |
| 30 | Extension housing (gearbox adaptor) |
| 31 | Stem extension |
| 32 | Stop part |
| 33 | T-key |
| 33A / 33B | Gearbox options |
Materials are given in the order-specific drawing and parts list / Malzemeler siparişe özel çizim ve parça listesinde verilir
Considerations when selecting an underground ball valve
In addition to the general selection criteria for ball valves, the conditions of burial must be defined in the order.
- Fluid: the valve and sealing materials are selected according to whether the fluid is liquid or gas, whether it contains solid particles and whether it is corrosive or sour.
- Pressure and temperature: the maximum operating pressure and the minimum / maximum operating temperatures of the fluid must be known.
- Size and bore: full bore or reduced bore. Only full-bore valves are suitable for lines that will be cleaned or inspected with pigs.
- Line pipe data for the weld ends: outside diameter, wall thickness, material grade and specified minimum yield strength (SMYS) of the mating pipe, so that the pups and weld bevels can be matched to the line.
- Burial depth: the distance from the pipe axis to the finished ground level determines the stem extension height (H).
- Operation: T-key, gearbox with handwheel or actuator; position of the handwheel / indicator relative to the line.
- Vent, drain and sealant lines: which lines are required and how they will terminate at the surface.
- External coating and cathodic protection: the coating type must be compatible with the pipeline coating and with the cathodic protection system of the line.
- Compliance with standards: API 6D, ISO 14313, ASME B16.34 or the standard specified by the customer.
Packaging
- Batusan underground valves are cleaned and their weld ends / flanges are protected with caps against foreign objects. It is recommended not to remove the caps until the valve is welded or connected to the cleaned line.
- The weld bevels, the top works (T-key head or gearbox) and the ends of the vent, drain and sealant lines are protected against impact during shipment.
- Batusan valves are packaged and palletized in accordance with the Transportation, Storage, Packaging and Shipment procedure. Unless the customer specifies a special request, underground valves are shipped fixed on a wooden pallet or in a wooden box.
Storage
- Valves must never be stacked on top of each other. No load may be placed on the extension housing, on the vent / drain / sealant lines or on the top works.
- Valves should be stored upright on their supports or on the pallet, on firm and level ground, in a closed storage area protected from water, moisture and dampness.
- Valves must be stored in the position in which they were delivered (fully open); they must never be left in a half-open position, otherwise the ball surface may damage the seats.
- For long-term storage (min. 6 months), the end caps are opened, the unpainted surfaces (weld bevels, flange faces) are lubricated with anti-corrosion oil and the caps are closed again. The caps of the vent, drain and sealant lines must remain closed.
- The factory coating must be protected from damage and from long exposure to sunlight during storage.
Transport and lifting
- When opening the box and inspecting the valves, make sure that there is no damage caused by transportation, in particular to the coating, the weld bevels, the extension housing and the vent / drain / sealant lines.
- Lifting devices suitable for the valve weight must be used. Ball valves weighing more than 25 kg are lifted by their own lifting points, as shown in the lifting sketch supplied with the valve.
- Cloth (textile) slings must be used so that the coating is not damaged. Steel ropes or chains must not touch the coated surfaces.
- The gearbox, the actuator, the handwheel, the T-key, the top plate and the vent / drain / sealant lines must never be used for lifting the valve.
- The valve must not be dragged, rolled or laid on the extension housing. Impacts on the extension may bend the stem extension and prevent full opening or closing of the valve.
- For valve and occupational safety, the lifting equipment must always be double-checked before each lifting operation.
- The end protection caps must not be removed during lifting / transportation, to prevent foreign matter from entering the valve.
Label information
The label information must be checked when the valve is delivered and before it is installed in the line: standard, size, pressure class, pressure / temperature rating, body material, trim, face-to-face (end-to-end) length, date of manufacture and serial number. If the valve is supplied with pipe pups, the actual overall length including the pups is given on the label.
Points to be considered when using underground ball valves
- The valve must be left in the fully open or fully closed position. A valve left in the half-open position damages the ball seals owing to its working principle and causes the valve to leak.
- Direction of operation: the valve closes when the T-key or the handwheel is turned clockwise.
- Position indicator: the indicator at the top of the extension is in line with the pipe when the valve is open and transverse to the pipe when the valve is closed. The valve position must always be confirmed on the indicator.
- T-key operation: fit the T-key completely onto the operating head before turning it. A quarter turn (90°) opens or closes the valve; do not apply force once the stop has been reached.
- Gearbox operation: turn the handwheel until the gearbox indicator shows the fully open or fully closed position. The gearbox end stops are set at the factory and must not be changed.
- Do not use extension bars: never lengthen the T-key or the handwheel with pipes or bars. The valve is designed in accordance with API 6D so that it can be operated by hand with the T-key or handwheel supplied. If the valve cannot be operated with normal force, stop and follow Section 8.E.
- Operating conditions: the maximum operating pressure (in bar) and the temperature limits are given on the valve label; the valve must not be operated outside these values.
- Operator safety: the operator must use protective equipment appropriate to the chemical and physical effects to which he or she may be exposed. In natural gas service, work in the valve box must be carried out with gas detection and without ignition sources.
Considerations when installing underground ball valves
Checks before installation
- The valve label information (standard, pressure class, size, end connection) must be compared with the pipeline information and compatibility must be verified.
- The pup material, wall thickness and bevel must match the line pipe and the welding procedure.
- The stem extension height must suit the trench depth, so that the operating head will be at the planned level in the valve box after backfilling.
- The coating must be checked visually for damage; damaged areas must be repaired with a coating material compatible with the factory coating before burial.
- The valve must be operated once from fully open to fully closed and back to fully open, and the position indicator must be checked. The valve is installed in the fully open position.
- If a flow direction or a preferred sealing direction is marked on the valve, it must be installed accordingly; otherwise it can be installed in either direction.
Welding the valve into the line
- Before the valve is placed, the pipeline must be cleaned of burrs, rust, welding residues, sand and dirt.
- Welding must be carried out by qualified welders, using a welding procedure qualified to the pipeline code (for example API 1104, ASME B31.4 / B31.8 or EN 12732).
- The valve must be in the fully open position during welding, so that the ball and seats are protected from welding spatter and heat.
- Welding is carried out only at the ends of the pups. No welding, cutting or heating may be done on the valve body, the extension housing or the lines.
- The pups keep the heat of the girth weld away from the seats. The temperature on the valve body next to the pup must not exceed the limit of the seat and seal materials; check it with temperature indicating crayons. If the limit is not stated in the order documents, consult Batusan before welding.
- The welding earth (ground) clamp must be connected to the pipe on the same side as the weld, never to the valve body, the extension or the top works, so that the welding current does not pass through the ball and seats.
- The axes of the pipes and the valve must be aligned. The valve must not be used to pull the pipe ends together; misalignment causes excessive stresses on the valve and jeopardises sealing.
- After welding and non-destructive testing, the girth welds must be coated with a coating system compatible with the pipeline and the valve coating.
Flanged connections and sealing elements
- If the valve has flanged ends, the bolt hole axes must be on the same axis; the gaps are first closed by tightening the bolts crosswise, then the bolts are tightened crosswise, in the sequence and to the torque values given in Section 12.
- A sealing element suitable for the type and pressure of the fluid must be selected; its surfaces must be smooth and it must not obstruct the valve bore.
- Dismantled or deformed sealing elements must not be reused; a new one must be installed.
- Buried flanged joints and bolts must be protected against corrosion together with the valve coating.
Stem extension, operating head and lines
- The extension housing must stand vertically. The stem extension must not be bent, shortened or welded on site.
- The extension housing and its connections are sealed against the ingress of water and soil. Its seals and covers must not be removed or damaged.
- The vent, drain and sealant lines are rigid pipes fixed to the valve and to the extension, terminating near the top of the extension. They must not be bent, loaded or used as a step; their end valves and caps must remain closed.
- If the gearbox or actuator is removed for any reason, its mounting position must be marked beforehand so that the indicator shows the correct valve position after refitting. Bolts are tightened according to Section 12.
Burial, bedding and backfilling
- The trench bottom under the valve must be level and compacted. The valve is laid on a sand bed or on a support pad so that its weight is carried by the soil and not by the pipeline.
- Before backfilling, the coating of the valve, pups and girth welds must be checked for holidays (for example with a holiday detector) and repaired.
- The valve, the extension and the lines must be surrounded with sand or fine, stone-free material. The backfill is placed and compacted in layers on both sides of the valve at the same time; compaction machines must not hit the valve, the extension or the lines.
- The valve box must be placed on its own foundation. It must not rest on the extension housing or on the lines, so that traffic and soil loads are not transferred to the valve.
- The operating head and the ends of the lines must remain accessible inside the valve box and must be protected from water and soil.
- The valve is part of the cathodic protection system of the pipeline. Measurements and connections are made according to the cathodic protection design of the line.
- The location of the valve must be marked on the surface and recorded on the as-built drawings.
Line cleaning and pressure testing
- After welding and before the first operation of the valve, the line must be cleaned (flushing or pigging). Welding slag, sand and scale damage the ball and seats when the valve is operated.
- Pigs may only be passed through the valve when it is fully open.
- The pressure test of the line is carried out according to the pipeline design code, with the valve fully open. The test pressure must not exceed the shell test pressure given in the valve test certificate.
- If a test is made against the closed valve, the pressure must not exceed the seat test pressure given in the valve test certificate.
- After a hydrostatic test, the body cavity must be drained through the drain line, to prevent corrosion and freezing.
Commissioning
- Confirm that line cleaning and the pressure test have been completed and that all vent, drain and sealant line valves are closed and capped.
- Operate the valve through one full open-close-open cycle and check that the position indicator agrees with the valve position.
- Measure and record the opening and closing torque, and keep this value as the reference for later inspections.
- Check the vent, drain and sealant line terminations and the valve box for leaks.
- Record the valve serial number, location, burial depth and commissioning date in the valve file.
Periodic check and preventive maintenance
Routine maintenance cannot be performed on underground valves; however, a preventive maintenance and inspection programme is required once a year. The fully welded body cannot be dismantled, so the internal parts cannot be replaced in the field.
Annual inspection
- Accessibility, cleanliness and condition of the valve box and its cover; water or soil inside the box
- Corrosion, coating and paint condition of the operating head, the top plate and the line ends
- Gas or liquid leaks at the operating head and at the vent, drain and sealant line terminations
- Position indicator: agreement with the actual valve position
- Operation of the valve: where the service allows, one full open-close cycle; the operating torque is compared with the commissioning value. Valves that remain in one position for a long time may need a higher breakaway torque.
- Internal tightness of the seats through the vent line (see 8.D)
- Condition of the sealant injection fittings and the caps
- Cathodic protection potential at the valve location (by the pipeline operator)
If signs of nonconformity are found during the check, they are recorded in the report; the relevant persons are notified and troubleshooting service is requested.
Maintenance preparation
- Find the instructions and drawings (drawing numbers / ref. no.) of the valve. Maintenance must not be performed without instructions and drawings.
- Check the safety of the work area and the traffic around the valve box.
- If there are flammable or explosive substances, pressure, air pollutants or poisonous substances, warn the relevant persons to remove them; measure the gas concentration in the valve box before starting work.
- Have the necessary tools, the injection equipment, the sealing grease, the seat cleaner and, if present, the gearbox or actuator manual ready.
Failure to comply with any of these procedures may pose a serious health and safety hazard to personnel.
Lubrication and sealant injection
- Sealant is injected from the injection fittings at the upper end of the sealant lines, inside the valve box.
- First, a special-purpose Batusan seat flush cleaner is injected. This removes old grease and foreign materials, which would cause leakage and high torque, from the sealing area.
- Then, with the valve fully closed, Batusan sealing grease selected according to the fluid is injected slowly on the high-pressure side. If possible, the ball is moved slightly so that the grease is distributed over the ball surface.
- The injection pressure must not exceed the maximum injection pressure stated by Batusan for the valve.
- Damaged injection fittings can be replaced while the line is under pressure only after it has been confirmed that the check valve in the fitting is working.
- Waste from lubrication must be collected and disposed of in accordance with the “Waste Management” procedure.
Control procedure (body cavity)
- Confirm the safety precautions for the check.
- Close the valve fully and confirm it on the position indicator.
- Slowly open the vent (or drain) line valve and relieve the pressure in the body cavity to a safe location.
- After the cavity pressure has been relieved, observe the flow at the vent line. A continuing flow indicates leakage through the seats; measure it against the API 6D leakage tolerances (bubble counting with a tube is sufficient).
- If the leakage exceeds the standard values, record it and apply sealant injection according to 8.C; if the leakage continues, contact Batusan technical service.
- Close the vent line valve, refit the cap and return the valve to its operating position.
Troubleshooting
| Symptom | Possible cause | Action |
|---|---|---|
| The valve cannot be operated with normal force | Long period without operation; dried sealant; dirt or ice on the operating head; gearbox fault | Do not use extension bars. Clean the head, check the T-key fit, inject seat cleaner and grease (8.C). If unsuccessful, contact Batusan. |
| Position indicator does not agree with the valve position | Gearbox / head refitted in a wrong position; loose indicator | Stop operating. Check the mounting marks (6.4) and the gearbox manual; contact Batusan if necessary. |
| Leakage through the closed valve | Valve not fully closed; seat damage by welding slag or debris | Confirm full closing; check through the vent line (8.D); inject sealant (8.C); record and inform Batusan. |
| Leakage at the vent, drain or sealant line ends | Line valve not fully closed; missing cap; damaged fitting | Close the line valve and fit the cap; replace fittings only according to 8.C. |
| Water or soil in the valve box | Displaced cover; settlement of the box | Clean and repair the box; check the operating head and extension seals for corrosion and water ingress. |
| Coating damage or corrosion on exposed parts | Mechanical damage; insufficient protection | Repair the coating; inform the cathodic protection operator. |
Venting and draining
The body cavity is pressurised during venting and draining. This dangerous operation should be performed by experienced personnel.
Venting and draining are carried out only through the valves at the upper ends of the vent and drain lines. Fittings, plugs or caps of a pressurised line must never be loosened or removed before the pressure has been completely relieved.
The line valve must be opened slowly. In gas service, the gas must be released to a safe location, away from people and ignition sources.
The fluid in the pipeline may be toxic, corrosive or flammable. The operator must use protective equipment suitable for the chemical and physical effects to which he or she will be exposed.
If a safety valve is available to prevent the uncontrolled release of fluid that may be harmful to human health, it is recommended that it be connected to a suitable manifold so that the released fluid can be controlled.
Tools used for work on the external surfaces of the valve and in the valve box (grinding, cutting, etc.) must be of the non-sparking type and their use must be subject to a permit. This permit is not valid in the presence of an explosive atmosphere.
Maintenance marking
Copy the records made in the maintenance document to the valve file. If service has been performed, add it to the service attachment. Adjustment and measurement records (operating torque, vent line check), the opinions of the maintenance staff and suggestions for future maintenance are stated on the service form.
Apply the field service label in the valve box and record the latest maintenance date. This period should not be more than 12 months.
Decommissioning and disposal
At the end of its service life, the valve is removed from the line by cutting the pups, after the line section has been isolated, depressurised, drained and purged. Hot work may only be carried out with a permit and after it has been confirmed that there is no explosive atmosphere.
The valve may contain toxic, corrosive and harmful substances, also in the body cavity and in the lines. It must be cleaned before dismantling, and the personnel must wear protective equipment appropriate to the contamination. Leakage at the cut ends must be prevented from contaminating the soil.
The coating and paint are removed; residual metallic parts can be recycled in a steel mill. Plastic parts (O-rings, seat inserts, packing rings, etc.) and wastes must be disposed of in accordance with European, national, regional and municipal directives and/or waste laws and/or hazardous material laws.
Additional documents
- Order-specific general arrangement drawing (stem extension height, pups, lines)
- Parts list and materials (order document; refer to the order file)
- Lifting sketch (valves heavier than 25 kg)
- Test certificate and material certificates
- Gearbox / actuator manual (if supplied)
Bolt tightening sequence and torque values
The tightening sequence and torque values below apply to the flanged end connections and to the bolted connections of the top works (gearbox / actuator mounting).
Bolt tightening torques (N·m) according to bolt grade
| Thread | Wrench N (mm) | Allen key A (mm) | Tightening torque by bolt grade (N·m) | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 3.6 | 4.6 | 5.6 | 5.8 | 6.8 | 8.8 | 9.8 | 10.9 | 12.9 | |||
| M1.6 | 3.2 | – | 0.06 | 0.08 | 0.09 | 0.12 | 0.15 | 0.19 | 0.22 | 0.27 | 0.32 |
| M2 | 4 | – | 0.13 | 0.15 | 0.19 | 0.25 | 0.29 | 0.39 | 0.42 | 0.53 | 0.64 |
| M2.5 | 5 | – | 0.22 | 0.29 | 0.36 | 0.48 | 0.58 | 0.78 | 0.87 | 1.09 | 1.31 |
| M3 | 5.5 | – | 0.38 | 0.51 | 0.63 | 0.84 | 1.01 | 1.35 | 1.52 | 1.90 | 2.27 |
| M4 | 7 | – | 0.71 | 0.95 | 1.19 | 1.59 | 1.91 | 2.54 | 2.86 | 3.57 | 4.29 |
| M5 | 8 | – | 1.71 | 2.28 | 2.85 | 3.80 | 4.56 | 6.09 | 6.85 | 8.56 | 10.30 |
| M6 | 10 | – | 2.94 | 3.92 | 4.91 | 6.54 | 7.85 | 10.50 | 11.80 | 14.70 | 17.70 |
| M8 | 13 | – | 7.11 | 9.48 | 11.90 | 15.80 | 19.00 | 25.30 | 28.40 | 35.50 | 42.70 |
| M10 | 17 | 8 | 14.30 | 19.10 | 23.80 | 31.80 | 38.10 | 50.80 | 57.20 | 71.50 | 85.80 |
| M12 | 19 | 10 | 24.40 | 32.60 | 40.70 | 54.30 | 65.10 | 86.90 | 97.70 | 122 | 147 |
| M14 | 22 | 12 | 39.00 | 52 | 65 | 86.60 | 104 | 139 | 156 | 195 | 234 |
| M16 | 24 | 14 | 59.90 | 79.90 | 99.80 | 133 | 160 | 213 | 240 | 299 | 359 |
| M18 | 27 | 14 | 82.50 | 110 | 138 | 183 | 220 | 293 | 330 | 413 | 495 |
| M20 | 30 | 17 | 117 | 156 | 195 | 260 | 312 | 416 | 468 | 585 | 702 |
| M22 | 32 | 17 | 158 | 211 | 264 | 352 | 422 | 563 | 634 | 792 | 950 |
| M24 | 36 | 19 | 202 | 270 | 337 | 449 | 539 | 719 | 809 | 1011 | 1213 |
| M27 | 41 | 19 | 298 | 398 | 497 | 663 | 795 | 1060 | 1193 | 1491 | 1789 |
| M30 | 46 | 22 | 405 | 540 | 675 | 900 | 1080 | 1440 | 1620 | 2025 | 2430 |
| M33 | 50 | 24 | 550 | 734 | 917 | 1223 | 1467 | 1956 | 2201 | 2751 | 3301 |
| M36 | 55 | 27 | 708 | 944 | 1180 | 1573 | 1888 | 2517 | 2832 | 3540 | 4248 |
| M39 | 60 | 27-30 | 919 | 1226 | 1532 | 2043 | 2452 | 3269 | 3678 | 4597 | 5517 |
| M42 | 65 | 32 | 1139 | 1518 | 1898 | 2530 | 3036 | 4049 | 4555 | 5693 | 6832 |
| M45 | 70 | – | 1425 | 1900 | 2375 | 3167 | 3800 | 5067 | 5701 | 7126 | 8551 |
| M48 | 75 | 36 | 1716 | 2288 | 2860 | 3813 | 4576 | 6101 | 6864 | 8580 | 10296 |
| M52 | 80 | 36 | 2210 | 2947 | 3684 | 4912 | 5895 | 7859 | 8842 | 11052 | 13263 |
| M56 | 85 | 41 | 2737 | 3650 | 4562 | 6083 | 7300 | 9733 | 10950 | 13687 | 16425 |
| M60 | 90 | 46 | 3404 | 4538 | 5673 | 7564 | 9076 | 12102 | 13614 | 11018 | 20422 |
| M64 | 95 | 46 | 4100 | 5466 | 6833 | 9110 | 10932 | 14576 | 16398 | 20498 | 24597 |
| M68 | 100 | 50 | 4963 | 6617 | 8271 | 11029 | 13234 | 17646 | 19851 | 24814 | 29777 |
| M72 | 105 | 55 | 6913 | – | 9228 | – | 17785 | 21074 | – | 29631 | 35537 |
| M76 | 110 | 60 | 8275 | – | 11047 | – | 21290 | 25227 | – | – | – |
| M80 | 115 | 65 | 9625 | – | 12849 | – | 24763 | 29341 | – | – | – |
| M90 | 130 | 70 | 14298 | – | 24941 | – | 36271 | 42978 | – | – | – |
| M100 | 145 | – | 19613 | – | 26182 | – | 50460 | 59790 | – | – | – |
| M110 | 155 | – | 26391 | – | 35230 | – | 67898 | 80463 | – | – | – |
| M120 | 175 | – | 34588 | – | 46174 | – | 88990 | – | – | – | – |
| M130 | 185 | – | 44300 | – | 59159 | – | 114015 | – | – | – | – |
| M140 | 200 | – | 55706 | – | 77568 | – | 143321 | – | – | – | – |
| M150 | 210 | – | 68906 | – | 91986 | – | 177281 | – | – | – | – |
Conclusion
An underground valve can no longer be reached once it has been buried. Its long service life therefore depends mainly on correct transport, welding, coating and backfilling, and on cleaning the line before the valve is operated for the first time.
The UNDERGROUND BALL VALVE must be operated in the fully open or fully closed position, and the annual preventive maintenance and inspection programme must be applied, in order to prevent possible leaks and operating costs.
Fully Welded Ball Valve Maintenance & Safe Use Instructions Document
Download as PDF (English / Turkish)
Fully Welded Ball Valve Product Page
API 6D fully welded ball valve